Steps For Using Three Way Stopcock
2020年6月17日The venous (IV) dropper was connected to the Y port injection port three-way stopcock without changing the direction, causing the drug solution to pause for 30 minutes. After the syringe pump blockage alarm sounded, an error was found.
The patient end of the three-way stopcock is temporarily closed for operation. Because the flow of the patient is not connected, the infusion pump is blocked and the alarm is turned on again after the completion of the alarm procedure.
When using a three-way stopcock, check the position of the stopcock/rod.
In many cases, it is necessary to confirm the position of the cock/rod. Develop a habit, confirm the flow of the drug solution after each use and operate the three-way stopcock.
The fluid paths indicating "closed" and "opened" For the 1 and 3 lever models, the cock/rod positions are reversed
Type the stopcock. Make sure to confirm the fluid channel and cock/rod.
Do not rotate 180°
Plug valve exceeds 180°! , May cause the drug solution to leak)
Connect the stopper/valve and intravenous drip tube to the three-way stopcock valve to administer antibiotics. After administration of antibiotics, the stopper and intravenous drip accidentally removed the tube and the patient’s blood leaked
When removing the IV tube from the three-way stopcock, make sure not to accidentally remove the stopper/valve.
It is good to have a "three-way plug valve" with a built-in plug/valve. Be sure to check whether the plug valve you are using has a built-in plug/valve.
Several three-way stopcock valves are connected to the central venous catheter. After lying down for a period of time, the connection between the three-way cock was loose, and blood and infusion leaked.
If you need to connect multiple three-way stopcocks together, please be cautious about joints loosening and breaking the body due to being squeezed or pulled. Regularly check whether the joints or fluids are loose and/or displaced
Leaks, etc.
When the three-way stopcocks are connected together, there is joint breakage or looseness. Avoid connecting tees
Plug valves are as close together as possible.
Our Three Way Stopcock selects the life-long injection mould of medical equipment, which can be used for multi-channel and multi-infusion treatment, and the rotation is flexible and unrestricted. Choose our products so that you can use it without worries: https://www.medicalmould.net/product/transfusion-bloodset-mould/stopcocks-mould/
The patient end of the three-way stopcock is temporarily closed for operation. Because the flow of the patient is not connected, the infusion pump is blocked and the alarm is turned on again after the completion of the alarm procedure.
When using a three-way stopcock, check the position of the stopcock/rod.
In many cases, it is necessary to confirm the position of the cock/rod. Develop a habit, confirm the flow of the drug solution after each use and operate the three-way stopcock.
The fluid paths indicating "closed" and "opened" For the 1 and 3 lever models, the cock/rod positions are reversed
Type the stopcock. Make sure to confirm the fluid channel and cock/rod.
Do not rotate 180°
Plug valve exceeds 180°! , May cause the drug solution to leak)
Connect the stopper/valve and intravenous drip tube to the three-way stopcock valve to administer antibiotics. After administration of antibiotics, the stopper and intravenous drip accidentally removed the tube and the patient’s blood leaked
When removing the IV tube from the three-way stopcock, make sure not to accidentally remove the stopper/valve.
It is good to have a "three-way plug valve" with a built-in plug/valve. Be sure to check whether the plug valve you are using has a built-in plug/valve.
Several three-way stopcock valves are connected to the central venous catheter. After lying down for a period of time, the connection between the three-way cock was loose, and blood and infusion leaked.
If you need to connect multiple three-way stopcocks together, please be cautious about joints loosening and breaking the body due to being squeezed or pulled. Regularly check whether the joints or fluids are loose and/or displaced
Leaks, etc.
When the three-way stopcocks are connected together, there is joint breakage or looseness. Avoid connecting tees
Plug valves are as close together as possible.
Our Three Way Stopcock selects the life-long injection mould of medical equipment, which can be used for multi-channel and multi-infusion treatment, and the rotation is flexible and unrestricted. Choose our products so that you can use it without worries: https://www.medicalmould.net/product/transfusion-bloodset-mould/stopcocks-mould/